|本期目录/Table of Contents|

[1]黄 梅,王 颖,王卫萍,等.两种吸附抗生素血培养瓶对血流感染检测能力的比较[J].医学研究与战创伤救治(原医学研究生学报),2014,16(02):117-120.[doi:10.3969/j.issn.1672-271X.2014.02.002]
 HUANG Mei,WANG Ying,WANG Wei-ping,et al.Compare the detection ability of 2 kinds blood cultured bottle which can absorb the antibiotics[J].JOURNAL OF MEDICALRESEARCH —COMBAT TRAUMA CARE,2014,16(02):117-120.[doi:10.3969/j.issn.1672-271X.2014.02.002]
点击复制

两种吸附抗生素血培养瓶对血流感染检测能力的比较()

《医学研究与战创伤救治》(原医学研究生学报)[ISSN:1672-271X/CN:32-1713/R]

卷:
第16卷
期数:
2014年02期
页码:
117-120
栏目:
出版日期:
2014-03-20

文章信息/Info

Title:
Compare the detection ability of 2 kinds blood cultured bottle which can absorb the antibiotics
作者:
黄 梅1王 颖1王卫萍1史利宁1李东兵2邵海枫1李芳秋1
1.210002 江苏南京,南京大学医学院附属金陵医院解放军临床检验医学研究所;2.210000 江苏南京,解放军94608部队
Author(s):
HUANG Mei1WANG Ying1WANG Wei-ping1SHI Li-ning1LI Dong-bing2SHAO Hai-feng1LI Fang-qiu1.
1.Institute of Clinical Laboratory,Jinling Hospital Affiliated of Nanjing University,Nanjing,Jiangsu 210002,China;2.94608 Army of PLA,Nanjing,Jiangsu 210000,China
关键词:
血培养BACTEC PLUS树脂需氧培养瓶BacT/Alert FA活性炭需氧培养瓶血流感染
Keywords:
blood cultureBACTEC PLUS resin oxygen bottleBacT/Alert FA active carbon oxygen bottle (Bio-FA bottles)bloodstream infection
分类号:
R446.51
DOI:
10.3969/j.issn.1672-271X.2014.02.002
文献标志码:
A
摘要:
目的 比较具有吸附抗生素能力的2种血培养瓶,即BACTEC PLUS树脂需氧瓶(简称BD-P瓶)与BacT/Alert FA活性炭需氧瓶(简称Bio-FA 瓶)对血流感染的检测能力。 方法 每位患者从两个不同部位采集血标本分别注入BD-P瓶和Bio-FA瓶,放入相应培养仪进行培养,记录报阳时间。结合临床用药资料对这2种具有不同吸附剂的血培养瓶的阳性检出率及报阳时间进行比较。 结果 在6670瓶血培养中阳性报警共1017瓶,确认污染196瓶(2.94%),有临床意义的阳性821瓶(12.31 %)。共检出病原菌493株,其中双瓶阳性334例(67.75%);BD-P瓶单瓶阳性102例(20.69%),Bio-FA瓶单瓶阳性57例(11.56%)。BD-P瓶对病原菌的检出率优于Bio-FA瓶(P<0.01),对于肠杆菌科和葡萄球菌的检出率BD-P瓶明显高于Bio-FA瓶(P<0.01)。BD-P瓶细菌报阳时间早于Bio-FA瓶(P<0.01),特别是对肠杆菌科和非发酵菌的阳性报警时间明显早于Bio-FA瓶。由正在使用药物治疗的患者中检出344例阳性,其BD-P瓶的阳性检出率和报阳时间均高于和快于Bio-FA瓶(P<0.05);按不同的治疗药物进行分组,对头孢哌酮/舒巴坦BD-P瓶的吸附能力更强(P<0.05)。结论 应用BD-P瓶检测血流感染较Bio-FA瓶检出率更高,检测速度更快。而联合使用Bio-FA瓶和BD-P瓶,比单用一种培养瓶更具优势。
Abstract:
Objective To compare the detectability to the bloodstream infection by 2 kinds bottles of BACTEC PLUS resin oxygen bottle (BD-P bottles) and BacT/Alert FA active carbon oxygen bottle (Bio-FA bottles).Methods All blood samples of patients from two different parts were injected into BD-P bottles and Bio-FA bottles and cultured in the blood culture system,record positive time.The positive rate and positive time of 2 different adsorbent blood culture bottles were compared combining with clinical data.Results There are 1017 positive bottles between the 6670 bottles,196 bottles were confirmed pollution,accounted for 2.94%;the clinical significance of the positive 821 bottles,accounted for 12.31%.493 pathogenic strains were detected,of which two bottles was positive in 334 patients (67.75%),single BD-P bottle was positive in 102 cases (20.69%);single Bio-FA bottle was positive in 57 cases (11.56%).The detection rate of Bio-FA bottle was higher than that of BD-bottle P (P<0.01),especially for the detection of Enterobacteriaceae and Staphylococcus.BD-P bottle bacteria Bao Yang predates the Bio-FA bottle (P<0.01),especially the positive alarm time for Enterobacteriaceae and non fermentive bacteria significantly earlier in Bio-FA bottles.In 344 positive cases using drug treatment,the positive rate and time of BD-P were higher and faster than that of the Bio-FA bottle (P<0.05);and the adsorption ability of BD-P bottles to cefoperazone/sulbactam was stronger than that of the Bio-FA bottle (P<0.05) according to different therapeutic drugs.Conclusion The detectability of BD-P bottles to the bloodstream infection was higher and faster than that of Bio-FA bottles.Combination of Bio-FA bottle and BD-P bottle was more advantage than using a single bottle.

参考文献/References:

[1] 张 丽,侯毅翰,张民伟,等.降钙素原在血流感染中的临床应用分析[J].东南国防医药,2013,15(6):603-605.
[2] Zadroga R,Williams DN,Gottschall R,et al.Comparison of 2 blood culture media shows significant differences in bacterial recovery for patients on antimicrobial therapy[J].Clin Infect Dis,2013,56(6):790-797.
[3] Gaieski DF,Mikkelsen ME,Band RA,et al.Impact of time to antibiotics on survival in patients with severe sepsis or septic shock in whom early goal-directed therapy was initiated in the emergency department[J].Crit Care Med,2008,38:1045-1053.
[4] Weinstein MP,Doern GV.A critical appraisal of the role of the clinical microbiology laboratory in the diagnosis of bloodstream infections[J].J Clin Microbiol,2011,49:S26-29.
[5] 高晓东,胡必杰,周春妹.两种血培养瓶在含抗菌药物血样中检测细菌的性能比较[J].中华医院感染学杂志,2009,19(6):708-712.
[6] 尤 涛,康 炜.BacT/ALER和伯泰血培养瓶对模拟菌血症标本检测能力对比分析[J].现代检验医学杂志,2010,25(1):107-108.
[7] 赵旺胜,王 珏,文 怡,等.双侧双瓶血培养在临床应用的初步研究[J].临床检验杂志,2011,30(1):10-12.
[8] 王 颖,史利宁,范 明,等.Bactec FX 和Bact/Alert 3D 两种血培养系统对菌血症的检出性能分析[J].临床检验杂志,2011,30(2):13-15.
[9] Patel R,Vetter EA,Harmsen WS,et al.Optimized pathogen detection with 30-compared to 20-milliliter blood culture draws[J].J Clin Microbiol,2011,49:4047-4051.
[10] McDonald LC,Weinstein MP,Fune J,et al.Controlled comparison of BacT/ALERT FAN aerobic medium and BACTEC fungal blood culture medium for detection of fungemia[J].J Clin Microbiol,2001,39:622-624.
[11] Flayhart D,Borek AP,Wakefield T,et al.Comparison of BACTEC PLUS blood culturemedia to BacT/Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics[J].J Clin Microbiol,2007,45(3):816-821.
[12] 李 惠,宋 珍,倪语星.两种需氧血培养系统对模拟菌血症检测能力的比较[J].检验医学杂志,2008,23(4):412-416.
[13] 孙景勇,周 敏,倪语星.延迟放瓶对两种血培养系统BacT/Al ERT 3D与BACTEC 9120 阳性检出率的影响[J].中华医院感染学杂志,2009,19(16):2210-2212.
[14] Akan QA,Yildiz E.Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/Alert 3D) on culture positivity[J].Diagn Microbiol Infect Dis,2006,54(3):193-196.

相似文献/References:

[1]张迪,初晓玲,楼小伟,等.203株血培养病原菌的分布和耐药情况分析[J].医学研究与战创伤救治(原医学研究生学报),2014,16(04):416.[doi:10.3969/j.issn.1672-271X.2014.04.027]

备注/Memo

备注/Memo:
国家青年自然科学基金项目(81302536)
更新日期/Last Update: 2014-03-20