|本期目录/Table of Contents|

[1]李熹,徐湘盛,胡敏,等.血液回收机在急诊大出血手术中的 临床应用观察[J].医学研究与战创伤救治(原医学研究生学报),2008,10(04):264.
 LI Zi,XU Xiang-sheng,HU Min,et al.Clinical observation of usage of ZITI-2000 Autologous Blood Recovery System in emergency bleeding surgery[J].JOURNAL OF MEDICALRESEARCH —COMBAT TRAUMA CARE,2008,10(04):264.
点击复制

血液回收机在急诊大出血手术中的 临床应用观察()

《医学研究与战创伤救治》(原医学研究生学报)[ISSN:1672-271X/CN:32-1713/R]

卷:
第10卷
期数:
2008年04期
页码:
264
栏目:
出版日期:
2008-07-20

文章信息/Info

Title:
Clinical observation of usage of ZITI-2000 Autologous Blood Recovery System in emergency bleeding surgery
文章编号:
1672-271X(2008)04-0264-03
作者:
李熹徐湘盛胡敏袁福华
解放军第123医院,安徽蚌埠233015
Author(s):
LI ZiXU Xiang-shengHU MinYUAN Fu-hua
Department of Anesthesiology,the 123th Hospital of PLA,Bengbu 233015,AnHui,China
关键词:
血液回收急诊出血手术
Keywords:
Autologous blood transfusionEmergency bleeding surgeryOperation
分类号:
R619
DOI:
-
文献标志码:
A
摘要:
目的观察ZITI-2000型血液回收机在急诊大出血手术的临床应用效果。方法用ZITI-2000型血液回收机对45例患者进行外科大出血手术中自体血液回输。同时监测患者生命体征(SBP、DBP、MAP、SpO2、CVP)的变化,并对患者术前血,术中回收血,术后静脉血进行血常规及血液生化检验。结果45例大出血患者回输血液后的生命体征与术前和回输前比较有明显的改善,并抢救成功,平均每例回收原血1 768 ml,经血液回收机处理后获得浓缩血平均每例687 ml,均输给患者。术后血常规、多项生化检查及血浆电解质检查结果均达到正常水平。除1例患者术后死于多脏器功能衰竭(MODS),其余患者术后恢复良好。结论 ZITI-2000型血液回收机能有效减少术中血液的丢失,减少输血后并发症。
Abstract:
ObjectiveTo observe the effect of intraoperative autologius blood transfusion by using ZITI-2000 Autologous Blood Recovery System in emergency bleeding surgery. MethodsIntraoperative autologous blood transfusion was performed in 45 patients subjected to surgery using ZITI2000 Autologous Blood Recovery System. SBP,DBP,MAP,SpO2 and CVP were monitored, routine and biochemical blood tests were examined for the blood samples taken before, after and during the operation.ResultsImportant signs had greatly improved for 45 patients with bleeding surgery after intraoperative autologius blood transfusion. The mean volume of 1,768 ml blood was collected from each patient during operation and 687 ml concentrated blood cells were got after processed with ZITI-2000 Autologous Becovery System in 45 patients.These blood cells were reinfused into the patents during operation. Routine blood tests, biochemical blood tests and serum electrolyte test were normal after operation. All patients recovered very smoothly except one patient who died of MODS.ConclusionZITI-2000 Autologous Blood Recovery System is very useful and efficacious for decrease loss of blood during operation and complications of homologus blood trasfusion.

参考文献/References:

[1]高折彦.自身输血[M].陈愉,张峙译.北京:人民军医出版社,1997:16-21.
[2]孙波.自体2000 型血液回收机在失血性休克抢救手术中的应用及术中配合[J].广州医药,2004,35(1):74-75.
[3]陈志良,任培土,阮新贤.自体血液回收在腹部创伤外科中的应用[J].中国输血杂志,2006,19(6):471-472.
[4]朱震,陈兵,张骏,等.自体血回输在心脏外科手术的应用[J].东南国防医药,2005,7(6):430-431.
[5]陈志良,任培土,阮新贤.自体血液回输在腹腔内出血治疗中的应用[J].浙江实用医学,2007,12(1):15-21.
[6]杜彦茹,张凤霞,张东,等.自体血液回收抢救术中大出血患者4例[J].中国输血杂志,2007,20(3):236-237.
[7]Cataldi S,Bruder N,Dufour H,et al.Intraoperative autologous blood transfusion in intracranial surgery[J]. Neurosurgery,1997,40(4):69-71.
[8]Smith LA,Barker DF,Burns RP.Autotransfusion utilization in abdominal trauma[J].Am Surg,1997,14(6):63.